Performance

Question: 

Is finger-jointed material allowed in the manufacturing of trusses?

Question: 

I am a structural engineer designing pool cage structures that are typically attached to the house at the fascia board. Sometimes, the structure is attached where trusses are behind the fascia board and other times there is a framed gable end overhang. Do you know of any information concerning this additional load on the trusses or overhang under design wind loads? Is there a limiting distance on the amount of overhang? I know trusses are designed for certain uplift and the pool cage will add to this uplift at design load, but what about the gable end overhangs?

Question: 

As a forensic engineer who has investigated numerous collapses of wood truss systems, I find your web site an excellent resource on the proper erection of wood trusses. What are your opinions on steel trusses, particularly with regards to installation and bracing? Do you feel that the installation and bracing techniques utilized for wood trusses are applicable to steel trusses? Do you know if that is the general industry standard or are there specific requirements and guidelines for steel trusses? Is there a particular guideline/commentary available for metal trusses?

Question: 

I am looking for some information regarding black surface mold on lumber. Does it alter the integrity of the lumber stress values? I have a client who wants to use “all dry” lumber for his construction but I do not know if this is really necessary.

Question: 

Some truss lumber repair nailing patterns call for 16d common nails. Most nail guns do not support 16d nails, but have an equivalent to a 12/10d nail. Is there a substitution guide or ESR report that could help us?

Question: 

I have been told that the high temperatures and low humidity present in attics can cause deterioration of wood, leading to truss failure. Is this true? If so, what length of time are we looking at and can we see the deterioration in the wood by visual inspection?

Question: 

I am investigating a roof failure in a 22-year-old structure. The connector plates have peeled open like a banana skin in several instances. The teeth do not appear sheared or torn at the wood surface. However, the plates will be in firm to one member and separated in the other (a gap of about 1/32 in.). Although there are large deformations, the roof is still standing. There was a heavy snow before the problem became apparent. Do you have any insights?

Question: 

I have built a 30 ft. x 40 ft. pole barn with nine 30 ft. 2x4 7/12 pitch trusses that are 5 ft. O.C. I am planning to finish out the interior and will attach 7/16 x 4 x 8 OSB sheets to the trusses for my ceiling. Along with this, I will have to add several 2x4 nailers across the 30 ft. span between the trusses to attach the sheeting to. My question is: will these trusses have any problem supporting this ceiling? I am not planning on anything being placed in the section above the ceiling and there will be no walls or supports erected between the ceiling and the floor.

Question: 

Does SBCA have any guidelines regarding the size of a room in an attic truss? I have used a formula, length of room in inches divided by the depth of the bottom chord equaling less than 22. I was curious if any extensive studies or published articles giving more exact guidelines are available.

Question: 

How much OSB can be stacked on a floor deck without damaging the trusses?