No matter the species, component manufacturers (CMs) purchase and rely on the accuracy and reliability of many different lumber design properties, including: bending (Fb); shear parallel to grain (Fv), compression perpendicular to grain (Fc^), compression parallel to grain (Fc), tension parallel to grain (Ft), and modulus of elasticity (E and Emin).
Framing the American Dream data suggests that installing roof trusses completes the task of framing a building’s roof in less time, requires less framer skill and experience and ultimately results in a roof that enables more open and flexible floor plans. SBCA, with the help of its members, has developed a wide variety of resources and tools to help component manufacturers design, build and deliver high quality roof trusses to their customers.
Framing the American Dream data suggests that installing floor trusses requires less framer skill and experience, results in a floor that requires less bearing locations and more effectively accommodates HVAC, plumbing and electrical infrastructure. SBCA, with the help of its members, has developed a wide variety of resources and tools to help component manufacturers design, build and deliver high quality floor trusses to their customers.
Framing the American Dream data suggests that installing wall panels completes the task of framing a building’s walls in less time, requires less framer skill and experience and ultimately results in a more reliable building envelope. SBCA, with the help of its members, has developed a wide variety of resources and tools to help component manufacturers design, build and deliver high quality wall panels to their customers.
According to industry surveys, lumber constitutes roughly 40 percent of the cost of manufacturing a structural component. As a consequence, an adequate supply of North American softwood lumber is vital to the success of component manufacturers. Insect infestations and wildfires (natural forces), as well as protectionist trade actions and logging restrictions (man-made forces) can have a significant impact on the available supply of lumber. Forces that constrain supply at a time when demand increases (i.e. growth in residential construction), can have a severely negative impact on the stability of lumber costs.
The potential for extensive damage during a fire event is greatest when a building is under construction because it is largely unprotected.
Fire Retardant Treated Wood (FRTW) products are permitted by code in certain situations where a fire resistance rating is required.
A variety of issues can lead to separation of drywall joints in walls and ceilings. Both environmental factors as well as installation and design factors can contribute to situations where gypsum may develop cracks. The issue has become more widespread as homeowners insist on larger rooms and open floor plans that have large clear span areas. By understanding how and why partition separation or ridging and cracking occur, and by following best practices, designers and builders can reduce the risk of unsightly and costly issues with gypsum board and drywall.
This information is intended to help employers understand their responsibilities regarding the I-9, how to conduct a self-audit, and how to prepare and respond to an HSI audit.
Per ANSI/TPI 1, truss-to-truss connections are under the scope of work of the truss designer. All other connections between a truss and another structural member (i.e. a wall or foundation) are the responsibility of the building designer.
The Occupational Safety and Health Administration (OSHA) regulates fall protection procedures for residential construction jobsites under 29 CFR 1926 Subpart M. These statutes provide minimum requirements for the mitigation of fall risks during erection.
During component installation, temporary restraint/bracing provides stability against unintended movement or loading prior to the application of exterior sheathing. Structural components are designed to withstand loading conditions over the course of the life of the structure under normal use conditions. However, during construction, insufficient temporary restraint/bracing may lead instability and even collapse under certain conditions such as high winds or seismic events. The resources below provide guidance on issues pertaining to the application of temporary restraint/bracing.
Permanent bracing and continuous lateral restraint is sometimes required within trussed systems to provide long-term stability and/or lateral force resistance. Individual structural components are designed to withstand loading conditions within a particular plane, so there are instances where the building designer may specify the use of permanent building stability bracing.
ANSI/TPI 1 Chapter 3 covers quality standards for the manufacture of metal plate connected wood trusses. It requires the use of a manufacturing quality assurance procedure, and period auditing by an approved inspection agency where required by local jurisdiction.
SBCA supports universal building installation of sprinklers for all types of construction, provided they are cost effective and do not create a competitive advantage for one structural element over another. When it comes to properly locating and designing sprinklers within a building, the IBC and IRC reference NFPA 13, 13D, and 13R (depending on the type of building). The resources below will assist the designer in understanding and implementing sprinkler systems in accordance with applicable building codes and referenced fire protection standards.
Integrating sprinkler systems into the open webbed configuration of metal plate connected wood trusses can be easy when following best practices. Truss construction can be manipulated with adjustments to panel lengths and web configurations to accommodate most special requirements. However, the Truss Designer needs to account for the additional weight of the sprinkler system and water. Additionally, construction loads encountered during installation need to be accounted for.
Mold can be found almost anywhere and can grow on virtually any substance, provided moisture is present. Mold differs from decay in that mold does not cause a decrease in the strength properties of lumber, however it can cause discoloration or odors on the lumber. The resources below will provide CM’s and builders with a better understanding of how mold can affect components, legal issues surrounding mold, as well as steps that can be taken to mitigate mold growth.
Field splicing is a method used to connect two or more truss sections into a single component. There are many reasons why field splicing may be used. A component may be too large or deep to manufacture, fit on a truck, or handle. A design modification or retrofit may necessitate a field splice, whether due to a change in truss profile or loading. Whatever the reason, field splices are another way to allow for greater flexibility in truss manufacturing, shipping and installation.
A truss may need to be modified or repaired due to accidental damage, holes or notches made by trades, errors in design or manufacturing, or a change requested by the customer. Trusses are typically designed for a specific application. Therefore, truss repairs or modifications must be analyzed on a case by case basis.
In the IECC, an air barrier is defined as “Material(s) assembled and joined together to provide a barrier to air leakage through the building envelope. An air barrier may be a single material or combination of materials.” The air barrier is an important part of integrated thermal and moisture control in a building. Many air barrier materials or strategies may be employed in a building that meet code requirements, however it is crucial to understand their interactions within the assembly.
Controlling sound transmission in buildings through wall, floor and ceiling assemblies is important for the comfort level and enjoyment of building occupants as they live, work and play in these buildings. Sound can come from a variety of sources: both internal to the building and environmental noise from the surrounding areas. The resources below explain how sound transmission is measured, and describe assemblies and other methods to limit noise transmission in buildings using components.
Do you have the right insurance for your business? Do your policies cover all your needs? A component manufacturer needs the right insurance to cover each activity within their scope of work. There are also safety programs, protocols, and other means a component manufacturer can implement to help keep insurance premiums low.
While marijuana remains illegal at the federal level, as of January 1, 2018, recreational marijuana is legal in nine states and medical marijuana is legal in 29 states. As more states legalize marijuana, for medical or recreational use, component manufacturers are confronted with potentially needing to adapt their drug policies. Since marijuana remains illegal on the federal level, there is no obligation to allow employees to use marijuana off the clock.
Investing in a standardized, comprehensive safety program minimizes the risks faced by both your employees and your company. SBCA’s customizable template materials, developed specifically for the component industry, can help you implement a consistent, measurable in-plant safety program through education, training and certification.
A cybersecurity breach can happen to anyone, anywhere. It’s become an all too common occurrence. Computer hackers do not target only large, Fortune 500 companies. In fact, criminals have begun to target small businesses, specifically because they rarely have the resources to fully protect themselves.
The Centers for Disease Control and Prevention recently reported that suicides are rising among the whole population, with male construction workers having the highest rate of suicide in the U.S. Dr. Debra Houry, director of CDC’s National Center for Injury Prevention and Control, points out that increasing suicide rates is a concerning trend that impacts the American workforce. “Knowing who is at greater risk for suicide can help save lives through focused prevention efforts,” says Dr. Houry.