Materials

Question: 

I am investigating a roof failure in a 22-year-old structure. The connector plates have peeled open like a banana skin in several instances. The teeth do not appear sheared or torn at the wood surface. However, the plates will be in firm to one member and separated in the other (a gap of about 1/32 in.). Although there are large deformations, the roof is still standing. There was a heavy snow before the problem became apparent. Do you have any insights?

Question: 

As a home inspector, I have recently inspected an existing home with an attic truss system installed. Several of the truss web members have been cut away to allow access to an attic-mounted heating system. Can you recommend repairs to a truss with cut web members?

Question: 

I am looking for a 1-hour roof/ceiling assembly for wood truss construction. I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control. Is this possible without using channels and what UL number would I use?

Question: 

Where can I find a copy of the criteria used to visually grade lumber?

Question: 

We have a local builder wishing to use floor trusses with a 2-hour assembly. I have shown him the 2-hour design on pages 17-27 of the second edition of SBCA’s Metal Plate Connected Wood Truss Handbook. Is this assembly UL approved? If so, what is the design number?

Question: 

What are the health hazards of black fungus on Douglas-Fir lumber?

Question: 

I am thinking of using wood trusses for the roofing/ceiling structural systems on some houses I shall build. I remember, though, an engineer/volunteer fireman commenting back in 1989 that the connector plates are prone to expand and pop off, early on in a fire, causing catastrophic structural failure. Was this the case, and if so, has this problem been corrected?

Question: 

I am trying to determine the manufacturer of some wood trusses installed in the early 1980s in New Jersey. The stamp mark on the connector plates reads, to the best of my ability, TPL-153A (it could be PPL or TPI, but I am unsure). I need to get in contact with this truss manufacturer in order to determine design loads for the truss, as I am remodeling the store under the roof.

Question: 

What is the life expectancy of wood that was used in an attic truss? Does fire retardant change the life expectancy?

Question: 

I would like to know if there is an age restriction on wood trusses. How long after production are they safe to use? The trusses in question are at least three to four months old. Are they still safe to use? They have not been covered the entire time and are showing signs of age.