Question: 

How do you evaluate whether a metal plate connected truss is still usable after exposure to fire? Are there any recommended tests?

Question: 

I was working on a job that had trusses that span more than 78 ft. with a 9/12 pitch. We had the #5 truss being installed when the #4 truss gave way. The trusses that were being installed are a two part system. The bottom set is what you would call hip trusses. The trusses contained 2x6 bottom chords, 2x8 top chords and rafters, and 2x4 webs. The roof sheathing was to be 3/4 in. plywood, 15 lb. felt paper and roof shingles. The ceiling was to be 5/8 in. drywall. The #4 truss sheared about 1 in. off the wall.

Question: 

I am a building designer on a salt storage building project. I would like to use metal plate connected wood trusses in the design. What should I specify for the metal connector plates?

Question: 

What type of wood is usually used for wood trusses? I live in Louisiana and I would guess pine, but I want to make sure.

Question: 

I have been hired by an insurance company to determine the extent of damage to roof trusses exposed to fire. How much fire damage compromises the structural integrity of the truss?

Question: 

I have been told that the high temperatures and low humidity present in attics can cause deterioration of wood, leading to truss failure. Is this true? If so, what length of time are we looking at and can we see the deterioration in the wood by visual inspection?

Question: 

A question has come up concerning sloped roof trusses and fire assembly ratings. Some are reluctant to rely on test results from flat (parallel chord) trusses applied to sloped roof trusses. Do you have any information regarding the suitability of the fire rated ceiling assemblies for sloped roof trusses? Does the “minimum depth” requirement of the parallel chord assembly apply to the minimum depth of a sloped roof truss (i.e., heel height?)

Question: 

I have a 29 x 72 mobile office with a 2-foot deep wooden truss above the ceiling that a client is required to sprinkler. Is there any way to avoid sprinklering above the gypboard ceiling?

Question: 

I am currently working on a project where a wood truss system was loaded with a heavy spring snow. I do not believe the load was beyond the truss's design capacity, but how do you know? Is there safety built into wood trusses? If the trusses were loaded beyond their design capacity, it would not have been for a long duration.

Question: 

Is it possible to construct an assembly for ceiling between first and second floors using 2x with few layers of gypsum to obtain a 3-hour fire rating?