Question: 

I am looking for some information regarding black surface mold on lumber. Does it alter the integrity of the lumber stress values? I have a client who wants to use “all dry” lumber for his construction but I do not know if this is really necessary.

Question: 

We have been using Turb-O-Webs for about four months. We are very happy with their performance, although there have been a few ripples along the way. The main thing that concerns me at present is the need for performance documentation and testing data. Do you have anything that will help, or know of people or organizations that could offer assistance?

Question: 

While building a new 2-story home, I found the need to use floor trusses between the 1st and 2nd floors. Is it true that I must also use roof trusses?

Question: 

We are planning to add 1/2 in. cement board and 3/8 in. quarry tile to a kitchen floor. We need to know if the floor trusses will handle the additional weight. The floor trusses are 19.2 in. O.C. and the loading numbers are 40-10-0-5. What do these numbers mean?

Question: 

Is it possible to construct an assembly for ceiling between first and second floors using 2x with few layers of gypsum to obtain a 3-hour fire rating?

Question: 

When you’re selling trusses through a lumberyard and the contractor calls to say that the “trusses don't fit correctly,” who has the ultimate responsibility for the trusses? I argue that the lumberyard is responsible since we have provided them with all the information on how the job was designed, even though they may or may not have passed this information on to the contractor.

Question: 

How high is a high heel?

Question: 

I am looking for help on the spacing required to screw down a BHP B-36 20 gage roof deck to wooden trusses spaced at 5 ft. 4 in. O.C. and 24 in. O.C. Do you know of any published codes or specifications on the above?

Question: 

I recall seeing a design recommendation several years ago regarding installation of hanger nails above the neutral axis of the bottom chord of a plated girder truss. The intent was to avoid dumping large loads into the bottom chord, below the neutral axis. Can you tell me where I can find this information?

Question: 

The Corps' guide spec for wood construction requires the drawings to indicate the design forces on each truss member for the worst loading condition. Loading conditions, of course, can include wind, snow build up, and unbalanced loading, to name a few. Many A/E firms submit drawings lacking these member forces, but instead show typical loading conditions. What does the wood truss fabricator want to see – truss diagrams with maximum loads on each member? Or would he prefer to design the truss from many required loading diagrams?