Question: 

Manufactured gable ends are actually frames even though they are often referred to as trusses. The webs are “studs” oriented vertically and usually spaced at 12, 16 or 24 in. O.C. The gable end frame is designed to transfer vertical loads from the roof to the continuous bearing wall below. Another way gable end frames are different from trusses placed in the interior of the structure is that frames experience perpendicular wind loads. The sheathed frame transfers the wind loads to the roof and ceiling diaphragms and vice versa.

Question: 

What tolerances are allowed for metal plate connectors in wood trusses? How do you take into account the possible presence of splits, waves and knots?

Question: 

In our one-year-old home, as you approach the hallway, the floor slopes downward. Our home inspector said that this was most likely due to the fact that the walls were resting on the floor as opposed to being load-bearing walls. What has been your experience with sloping floors in a new home? The floors are very flat elsewhere until the walls start. Do you think this sloping could turn into a structural problem eventually?

Question: 

I want to get a good definition on what causes “truss lift,” when the trusses will actually raise off the top plates of interior walls (even when nailed), causing the drywall to crack. Is it from drastically different temperatures in the attic and living area?

Question: 

Do you have any information on the use of in-floor radiant heat with 4x2 open-web floor trusses? Are there any adverse effects to the lumber as a result of moisture build up?

Question: 

Can a roof truss penetrate a one-hr. tenant separation wall without having a one-hr. rated ceiling? The building official insists that the 2x4 chords are combustible and nullify the integrity of the one-hr. rated partition that is constructed in an attic above an 8 in. C.M.U. bearing wall. The partition consists of gypsum board attached to 2 x 4 stud framing. The building official insists that a ledger must be attached through the gypsum board to support the trusses each side of the wall. This is almost saying that any rated assembly must have bearing only on other rated assemblies.

Question: 

I have built a 30 ft. x 40 ft. pole barn with nine 30 ft. 2x4 7/12 pitch trusses that are 5 ft. O.C. I am planning to finish out the interior and will attach 7/16 x 4 x 8 OSB sheets to the trusses for my ceiling. Along with this, I will have to add several 2x4 nailers across the 30 ft. span between the trusses to attach the sheeting to. My question is: will these trusses have any problem supporting this ceiling? I am not planning on anything being placed in the section above the ceiling and there will be no walls or supports erected between the ceiling and the floor.

Question: 

Is a Class A fire rating (provided by our liquid spray-on fire retardant) acceptable in certain situations?

Question: 

Are there any trusses that are supported strictly by the wood itself without any mechanical connections such as brackets?

Question: 

I am trying to determine the manufacturer of some wood trusses installed in the early 1980s in New Jersey. The stamp mark on the connector plates reads, to the best of my ability, TPL-153A (it could be PPL or TPI, but I am unsure). I need to get in contact with this truss manufacturer in order to determine design loads for the truss, as I am remodeling the store under the roof.