Residential Codes (IRC)

Question: 

I have mono trusses on either side of a firewall. I have the fire rating/wall material between them. Can I place a ridge vent above these two? Or should I use vents? How do I calculate the appropriate vent sizes and styles?

Question: 

In RC 2601, is RC-1 Channel used?

Question: 

I am reviewing a truss package that includes multi-ply trusses. Where do I find the requirements for the attachment of the individual trusses to each other (nails and/or bolts)? Is this a requirement that the structural engineer of record needs to supply or is it the responsibility of the truss manufacturer to design?

Question: 

In a small scale multi-family residential project, I'd like to use a wood truss floor-ceiling assembly to achieve a one hour separation between units. I'd like to directly attach the drywall to the underside of the trusses & use the truss space for ducts & lighting (the floor above will be lightweight concrete on plywood sub-floor). UL assemblies do not seem to address the duct/light penetrations in such an assembly. Can I achieve a one-hour rating in such an assembly and how are penetrations addressed? Can the ducts in the truss space serve both units above and below?

Question: 

I am currently putting together a set of truss specifications for a set of structural plans. I am interested to know of the most current publication that may specify industry standards in truss components (i.e. metal connector plates, wood quality and connection quality). Do you have any suggestions?

Question: 

Can I put a wood deck (1/2 in. plywood) on top of the bottom chord of a 26 foot span truss 24 inches on center?

Question: 

I need to obtain some information on fire-retardant-treated roof trusses.

Question: 

What type of construction uses a fire cut truss? Could you describe a fire cut truss?

Long span trusses can pose significant risk to installers. The dimensions and weight of a long span truss can create instability, buckling and collapse of one or many trusses, if not handled, installed, restrained and braced properly. As such, they require more detailed safety and handling measures than shorter span trusses. This research report provides guidelines for proper handling and installation of long span trusses for both wood and cold-formed steel.

ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures has revised Chapter 30 regarding Components & Cladding (C&C) wind loads on roofs. This report clarifies the type and scope of changes being made that will also change in the 2018 edition of the model building codes.