The lumber used in most metal plate connected wood trusses is either visually- or mechanically-graded solid sawn dimensional lumber. However, the Truss Plate Institute's ANSI/TPI 1 allows the use of structural composite lumber (SCL) products such as laminated veneer lumber (LVL), laminated strand lumber (LSL) and parallel strand lumber (PSL). These engineered wood products can conceivably compete with sawn lumber and complement it in truss designs.
Girders are trusses specially designed to carry extra loads that are a result of the structural framing members they support. Sometimes a single ply girder truss is insufficient to carry the entire load, so the truss designer designs a multiple-ply girder. This is where identical trusses are built and fastened together to act as one unit to support the load. ANSI/TPI 1 states that girder trusses up to three plies thick can be fastened together with nails. Girders over three plies must be pre-drilled and bolted rather than nailed.
I am a building designer on a salt storage building project. I would like to use metal plate connected wood trusses in the design. What should I specify for the metal connector plates?
Has there been any research or studies on long-term deflection of metal plate connected wood trusses? How much deflection is allowed?
We have designed a custom home that needs a good solid floor, with low vibration perceptibility. The system we have specified consists of 2 in. of gypcrete over 1 and 1/8 in. thick plywood or OSB. The floor trusses are 20 in. deep at 16 in. O.C., spanning 31 ft. 6 in. The preliminary truss design shows a double top and bottom chord with a total load deflection of 1.30 in. (l/290) and a live load deflection of 0.65 in. (l/581). The basement ceiling will be 1/2 in. gypboard nailed to the bottom of the trusses.
Some building designers believe that gable end webs need to be L-braced to 90% of the web length, which sounds fine. However, they spec that scissors gable end webs need to be braced to 100% of the web length. That means that in the field they are notching the braces to fit around top and bottom chords – you can imagine how difficult that can be. Is that necessary or even the intent of the web L-bracing?
Is there a chart available on the allowable amount of deflection on floor trusses?
Are there charts illustrating allowable HVAC duct sizes that can fit between truss chords for various truss depths?
Do you have sound rating information for floor truss assemblies (i.e., STC and IIC ratings)? We are looking specifically for ratings for 12 in. floor trusses, with 1 and 1/2 in. concrete topping and without the topping. We are looking to meet the minimum code rating of STC 45 and IIC 45.
What is the recommended standard spacing for open-web wood joists? I have seen them placed 24 in. O.C. Is this acceptable for a customer who will have an exercise room with 500 pounds of free weights? I understand there are problems with bouncy floors with 24 in. spacing. Is this true?
In our one-year-old home, as you approach the hallway, the floor slopes downward. Our home inspector said that this was most likely due to the fact that the walls were resting on the floor as opposed to being load-bearing walls. What has been your experience with sloping floors in a new home? The floors are very flat elsewhere until the walls start. Do you think this sloping could turn into a structural problem eventually?
Are there any typical wood truss span tables for roofs and floors available? Standard framing details for use in preliminary design?
Where can I find specs for what would be adequate trusses? I have a room with a 24 ft. span and my contractor is using trusses where the bottom plate is composed of 2x4s butted together and fastened with a metal plate. Is this ok?
If you have the condition where you are out by the max tolerances of 1/2 in., how do you correct the situation? Do you shim the truss from the bottom? Shim from the top? I will assume you do not shave the truss off. What is the published corrective action for situations that cannot handle the variation in truss height?
I am a structural engineer on a project with a wood trussed roof. I have noticed some variations in the peak height in a run of identical trusses. Do you have any information on tolerances for the final dimensions of manufactured trusses?
I am looking for help on the spacing required to screw down a BHP B-36 20 gage roof deck to wooden trusses spaced at 5 ft. 4 in. O.C. and 24 in. O.C. Do you know of any published codes or specifications on the above?
I am currently putting together a set of truss specifications for a set of structural plans. I am interested to know of the most current publication that may specify industry standards in truss components (i.e. metal connector plates, wood quality and connection quality). Do you have any suggestions?
I was wondering if you have any information or anecdotes relating to the deflection performance of long span scissors trusses? We recently sold a job with 70 ft. long scissors trusses. The customer is in the process of installing the trusses and doesn't like the deflections he is seeing. To make matters worse, the scissors trusses are framing into a valley set (which we provided) that is erected on 35 ft. Howe trusses. The Howe trusses are exhibiting very little deflection. Any ideas?
If the truss design drawing specifies using 2x4 1650F SPF, can 2x4 No. 2 southern pine be used instead? What are some things that need to be checked?
Our home has 2x4 roof trusses spanning 25 ft. spaced 16 in. O.C. Currently, there is limited attic storage on a plywood subfloor on the bottom chords, accessed via a small hatch in a closet. We would like to install a fold-down attic stair with a rough opening size of 25.5 in. x 54 in., with the long dimension perpendicular to the trusses. This would mean cutting the bottom chords of three trusses to frame the opening. Is this possible?
Is there any information relating to the cutting of gable studs in the field to place a louver or a window over a gable trussed end wall?
Is it possible to retrofit a standard rafter/joist style roof to a scissors truss configuration without replacing the existing construction?
I am a professional engineer looking for information concerning the failure of metal plate connected wood trusses and methods of repair. I am looking for this information with regard to developing recommendations for the repair of truss systems in the floor structures of two-story multi-family dwellings. I see frequent failure of truss systems of this type in both in bending and due to catastrophic failure at the gussets.
I need to know how to repair a hole that has been drilled through a truss. In installing the wiring we improperly put the wires through the truss and now need to know the proper way to repair it.
I have just moved into a new home and during the construction I noticed that one of the trusses in the garage was damaged. The web plate had come off in two different locations. I notified the builder and they said they would take care of it. Approximately two weeks after I moved in, I noticed the ceiling in the garage started to sag, so I went into the space above the garage and found the truss was never repaired. I again notified the builder and they sent someone to fix it. I went and looked at the fix and this is where my question comes in.
Occasionally we deal with truss failures due to impact and or crushing forces such as trees falling onto roof structures. At what point can the truss no longer be repaired? Also, what should an adjuster look for when determining repair-ability? Or should a storm adjuster basically punt and call a consultant for every truss failure?
As a home inspector, I have recently inspected an existing home with an attic truss system installed. Several of the truss web members have been cut away to allow access to an attic-mounted heating system. Can you recommend repairs to a truss with cut web members?
I have a four-year-old house with glued open-web trusses. Both the truss manufacturer and the builder have admitted to me that the trusses were installed wrong. I have a problem with the suggested repair. I have hired a structural engineer and he suggested installing a 2x10 between each truss and removing the old truss. This would have to take place on both the first and second floors because all the trusses were installed wrong. The manufacturers want to install six strongbacks on each floor, hoping this will tighten them up.