Frequently Asked Technical Questions

I own and live in the middle unit of a one-story tri-plex that has a truss-framed roof. The interior has high ceilings that would potentially allow the addition of a second floor room. I am contemplating adding a shed dormer to create a second story bedroom. Do you have any suggestions as to how a shed dormer could be added? I am familiar with how to frame up a shed dormer if the original framing were rafters and a ridge board, but the truss construction has thrown me for a loop.

I am building a home and want to use floor trusses. How can I find a local manufacturer?

I need to put a new roof on my single-family dwelling. The house originally had gable and soffit/eave vents. The roofing contractor suggested that we install a ridge vent when new roof is installed. Should the existing gable vents be blocked off or does it not matter? I have read some debates about whether or not the combination of gable and ridge vents substantially reduces the effect of the soffit vents by having the intake now at the gable vents and exhaust at the ridge. Would this type of ventilation affect the truss warranty?

How high is a high heel?

What is the definition of an energy heel?

I am doing research for clients who have flat roof trusses to which they are adding a second story. We are now looking for information on the trusses to determine what their load capability is. What do you need to know to help us determine this?

We are changing plans from a two story home to a one story home. The original roof pitch is 12/12 with three dormer windows, one large one in the center and a smaller one on either side. Can you tell us what pitch would be advisable under this new plan still using the dormers?

We have been using Turb-O-Webs for about four months. We are very happy with their performance, although there have been a few ripples along the way. The main thing that concerns me at present is the need for performance documentation and testing data. Do you have anything that will help, or know of people or organizations that could offer assistance?

We would like to know if there is a problem with using wood floor trusses with masonry bearing walls without a ledger. Our local supplier has told me that encasing the wood truss in the masonry wall could be detrimental to the truss due to moisture. What, if any, suggestions do you have for this condition? If a bottom chord bearing is used, do the trusses need fire cuts? The two-story building contains masonry bearing walls with wood trusses on the second floor and wood trusses at the roof.

We are experiencing problems with bouncy wood floor trusses. I'm wondering what the industry standard is on deflections (live and total load). Also, do you have any ideas on how to decrease the deflection without affecting the profit margin significantly?